Operations console

Customers

Crescent Plaza - Unit 2

32.0 kW Hybrid system in Faisalabad, commissioned 16 Mar 2022

System health

72

Performance ratio against baseline, less open defects

Generated (30 days)

2.9 MWh

80% of expected

Modelled soiling loss

19.7%

Last cleaned 22 Apr 2026

Performance ratio

67.5%

Baseline 84%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
32.0 kW
System type
Hybrid
Modules
58 x 555W Longi
Inverter
GoodWe DNS-G3-32K (28.8 kW)
Battery
5 kWh
Tilt / azimuth
14 deg / 180 deg
Bird mesh
Not installed
Tariff
Rs 49 per kWh
Net metering
Approved
NM reference
NM-2024-20404
Sanctioned
32 kW
AMC
Commercial Pro
Open findings

Unresolved defects on this site.

  • Loose structure bolt

    Minor

    Two mid-clamps below torque specification on the north row. Retorqued.

  • Inverter derating in afternoon peak

    Major

    Unit throttles above 46 degrees ambient. Cooling fins clogged with dust.

Work order history

4 visits

CodeServiceStatusAmount
JOB-2026-0101Insurance InspectionScheduledRs 9.5K
JOB-2026-0162Loose Connection FixInvoicedRs 3.6K
JOB-2026-0169Fuse ReplacementCompletedRs 1.9K
JOB-2026-0061Thermal Camera InspectionCancelledRs 22.4K