Operations console
Prototype - no backend
All work orders
Combiner Box Repair
JOB-2026-0059 - raised via Portal 5 mo ago
InvoicedHigh priorityAnnual Plus AMC
Checklist
6 of 6 steps complete
Findings
Defects recorded on site. Unresolved criticals roll up to the operations overview.
Bird nesting under array
MinorPigeons nesting between modules and roof. Bird mesh recommended for the full perimeter.
Open
Heavy soiling on lower rows
MinorDust accumulation reducing output on the two lowest rows more than the rest of the array.
Resolved
Inverter derating in afternoon peak
MajorUnit throttles above 46 degrees ambient. Cooling fins clogged with dust.
Resolved
Parts used
Consumed from van stock on this visit.
| Part | Qty | Unit cost | Line total |
|---|---|---|---|
| Earthing Rod 5ft | 2 | Rs 23,816 | Rs 47,632 |
| End Clamp 35mm | 3 | Rs 34,454 | Rs 103,362 |
Result
Generation either side of the visit.
+35 kWhper day
152 kWh before, 187 kWh after
Worth about Rs 48,300 a month at this site's tariff.
Assignment
Technician
Tahir MahmoodDetails
- Customer
- Chughtai Diagnostic Centre
- City
- Lahore
- Capacity
- 50.0 kW
- Raised
- 16 Mar 2026, 3:00 PM
- Scheduled
- 17 Mar 2026, 6:00 AM
- SLA due
- 17 Mar 2026, 3:00 PM (5 mo ago)
- Completed
- 17 Mar 2026, 6:00 AM
- Services
- Combiner Box Repair
- Amount
- Rs 7,800