Operations console

Customers

Nadia Rehman

7.5 kW On-Grid system in Faisalabad, commissioned 26 Feb 2020

System health

68

Performance ratio against baseline, less open defects

Generated (30 days)

720 kWh

86% of expected

Modelled soiling loss

6.6%

Last cleaned 16 Jun 2026

Performance ratio

71.2%

Baseline 83%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
7.5 kW
System type
On-Grid
Modules
14 x 555W Canadian Solar
Inverter
Fronius Primo-8K (6.8 kW)
Battery
None
Tilt / azimuth
14 deg / 190 deg
Bird mesh
Not installed
Tariff
Rs 55 per kWh
Net metering
In process
NM reference
NM-2026-80891
Sanctioned
8 kW
AMC
Annual Basic
Open findings

Unresolved defects on this site.

  • Hotspot detected on string B

    Critical

    Thermal scan shows a cell running 27 degrees above array average. Bypass diode failure suspected.

  • Inverter derating in afternoon peak

    Major

    Unit throttles above 46 degrees ambient. Cooling fins clogged with dust.

Work order history

5 visits

CodeServiceStatusAmount
JOB-2026-0118Commercial Solar InstallationRequestedRs 26
JOB-2026-0084On-Grid Solar SystemCancelledRs 27
JOB-2026-0095Hybrid Solar SystemCompletedRs 32
JOB-2026-0127Solar Panel RepairCompletedRs 53.2K
JOB-2026-0007Factory Solar MaintenanceInvoicedRs 32.0K