String Testing
RPT-2026-020 - performed 12 Feb 2026 by Tahir Mahmood
Health score
69
Measurements taken
6
3 outside reference
Findings
1
Customer visibility
Shared
Measurements
Each reading against the reference it is judged by.
| Measurement | Reading | Reference | Result |
|---|---|---|---|
| Open circuit voltage (string A) | 596 V | Within 5% of design | Pass |
| Short circuit current (string A) | 11 A | Within 8% of nameplate | Pass |
| Earth electrode resistance | 8.5 ohm | Below 5 ohm | Outside reference |
| Insulation resistance (DC+ to earth) | 43 Mohm | Above 1 Mohm | Pass |
| Max module temperature | 62 C | Below 25 C above ambient | Outside reference |
| Performance ratio on test day | 88% | Baseline 84% | Outside reference |
Context
- Customer
- Chughtai Diagnostic Centre
- Capacity
- 50.0 kW
- Work order
- JOB-2026-0067
- Technician
- Tahir Mahmood
Recommendation
Schedule corrective repair within 14 days. Losses at the current rate exceed the cost of the fix.
Score 69 / 100Findings
Defects recorded during this inspection.
No defects found
InfoResolvedSystem operating within expected parameters on the day of inspection.