Findings
Defects recorded on site. Unresolved criticals roll up to the operations overview.
Inverter derating in afternoon peak
MajorUnit throttles above 46 degrees ambient. Cooling fins clogged with dust.
Resolved
Heavy soiling on lower rows
MinorDust accumulation reducing output on the two lowest rows more than the rest of the array.
Resolved
Earthing resistance above limit
MajorMeasured 9.4 ohm against a 5 ohm reference. Earth pit needs re-treatment.
Open
Parts used
Consumed from van stock on this visit.
| Part | Qty | Unit cost | Line total |
|---|---|---|---|
| Combiner Box 4-in-1 | 3 | Rs 38,311 | Rs 114,933 |
| MC4 Connector Pair | 3 | Rs 33,125 | Rs 99,375 |
Result
Generation either side of the visit.
+1 kWhper day
21 kWh before, 22 kWh after
Worth about Rs 1,680 a month at this site's tariff.
Assignment
Technician
Faisal ShahzadDetails
- Customer
- Hina Qureshi
- Site
- Hina Qureshi
- City
- Rawalpindi
- Capacity
- 7.5 kW
- Raised
- 13 Jun 2026, 1:00 PM
- Scheduled
- 16 Jun 2026, 6:00 PM
- SLA due
- 15 Jun 2026, 1:00 PM (2 mo ago)
- Completed
- 16 Jun 2026, 6:00 PM
- Services
- Fuse Replacement
- Amount
- Rs 1,900