Operations console

All work orders

Waterless Panel Cleaning

JOB-2026-0076 - raised via Portal 2 mo ago

InvoicedNormal priorityAnnual Plus AMC
Checklist

6 of 6 steps complete

Findings

Defects recorded on site. Unresolved criticals roll up to the operations overview.

  • String mismatch on MPPT 2

    Major

    String currents differ by 18 percent, pointing to partial shading or module degradation.

    Resolved

Parts used

Consumed from van stock on this visit.

PartQtyUnit costLine total
Module 585W Mono4Rs 27,303Rs 109,212
Result

Generation either side of the visit.

+88 kWhper day

737 kWh before, 825 kWh after

Worth about Rs 113,520 a month at this site's tariff.

Assignment

Technician

Shoaib Akhtar
Details
City
Islamabad
Capacity
250.0 kW
Raised
9 Jun 2026, 3:00 PM
Scheduled
9 Jun 2026, 8:00 PM
SLA due
10 Jun 2026, 3:00 PM (2 mo ago)
Completed
9 Jun 2026, 8:00 PM
Services
Waterless Panel Cleaning
Amount
Rs 111,020