Operations console
Prototype - no backend
All reports
Thermal Camera Inspection
RPT-2026-026 - performed 1 May 2026 by Danish Ali
Health score
80
Measurements taken
6
1 outside reference
Findings
2
Customer visibility
Shared
Measurements
Each reading against the reference it is judged by.
| Measurement | Reading | Reference | Result |
|---|---|---|---|
| Open circuit voltage (string A) | 726 V | Within 5% of design | Pass |
| Short circuit current (string A) | 8.6 A | Within 8% of nameplate | Pass |
| Earth electrode resistance | 7.9 ohm | Below 5 ohm | Pass |
| Insulation resistance (DC+ to earth) | 79 Mohm | Above 1 Mohm | Outside reference |
| Max module temperature | 53 C | Below 25 C above ambient | Pass |
| Performance ratio on test day | 78% | Baseline 85% | Pass |
Context
- Customer
- Crescent Plaza
- Capacity
- 32.0 kW
- Work order
- JOB-2026-0090
- Technician
- Danish Ali
Recommendation
Bring cleaning forward by one cycle and re-torque the affected strings within 30 days.
Score 80 / 100Findings
Defects recorded during this inspection.
Loose structure bolt
MinorResolvedTwo mid-clamps below torque specification on the north row. Retorqued.
Warranty documents missing
InfoResolvedModule warranty pack not on file. Copies requested from the original installer.