RPT-2026-023 - performed 23 May 2026 by Shoaib Akhtar
Health score
81
Measurements taken
6
1 outside reference
Findings
1
Customer visibility
Internal only
Measurements
Each reading against the reference it is judged by.
| Measurement | Reading | Reference | Result |
|---|---|---|---|
| Open circuit voltage (string A) | 697 V | Within 5% of design | Pass |
| Short circuit current (string A) | 8.4 A | Within 8% of nameplate | Pass |
| Earth electrode resistance | 8.9 ohm | Below 5 ohm | Pass |
| Insulation resistance (DC+ to earth) | 83 Mohm | Above 1 Mohm | Pass |
| Max module temperature | 72 C | Below 25 C above ambient | Outside reference |
| Performance ratio on test day | 81% | Baseline 86% | Pass |
Context
- Customer
- Al-Noor Textile Mills
- Capacity
- 100.0 kW
- Work order
- JOB-2026-0113
- Technician
- Shoaib Akhtar
Recommendation
Bring cleaning forward by one cycle and re-torque the affected strings within 30 days.
Score 81 / 100Findings
Defects recorded during this inspection.
No defects found
InfoResolvedSystem operating within expected parameters on the day of inspection.