Operations console
Prototype - no backend
All reports
Thermal Camera Inspection
RPT-2026-018 - performed 1 May 2026 by Naveed Iqbal
Health score
94
Measurements taken
6
1 outside reference
Findings
3
Customer visibility
Internal only
Measurements
Each reading against the reference it is judged by.
| Measurement | Reading | Reference | Result |
|---|---|---|---|
| Open circuit voltage (string A) | 649 V | Within 5% of design | Pass |
| Short circuit current (string A) | 9.3 A | Within 8% of nameplate | Pass |
| Earth electrode resistance | 2.1 ohm | Below 5 ohm | Pass |
| Insulation resistance (DC+ to earth) | 79 Mohm | Above 1 Mohm | Outside reference |
| Max module temperature | 64 C | Below 25 C above ambient | Pass |
| Performance ratio on test day | 76% | Baseline 81% | Pass |
Context
- Site
- Imran Baig
- Customer
- Imran Baig
- Capacity
- 15.0 kW
- Work order
- JOB-2026-0077
- Technician
- Naveed Iqbal
Recommendation
System is healthy. Continue the current cleaning cycle and re-inspect in six months.
Score 94 / 100Findings
Defects recorded during this inspection.
Monitoring app not configured
InfoResolvedCustomer has no visibility of live generation. App setup offered.
Warranty documents missing
InfoResolvedModule warranty pack not on file. Copies requested from the original installer.
Heavy soiling on lower rows
MinorResolvedDust accumulation reducing output on the two lowest rows more than the rest of the array.