Operations console

All reports

Shade Analysis

RPT-2026-015 - performed 27 Jun 2026 by Faisal Shahzad

Health score

89

Measurements taken

6

0 outside reference

Findings

1

Customer visibility

Shared

Measurements

Each reading against the reference it is judged by.

MeasurementReadingReferenceResult
Open circuit voltage (string A)764 VWithin 5% of designPass
Short circuit current (string A)9.1 AWithin 8% of nameplatePass
Earth electrode resistance7.1 ohmBelow 5 ohmPass
Insulation resistance (DC+ to earth)47 MohmAbove 1 MohmPass
Max module temperature73 CBelow 25 C above ambientPass
Performance ratio on test day76%Baseline 84%Pass
Context
Capacity
250.0 kW
Work order
JOB-2026-0011
Technician
Faisal Shahzad
Recommendation

System is healthy. Continue the current cleaning cycle and re-inspect in six months.

Score 89 / 100
Findings

Defects recorded during this inspection.

  • No defects found

    InfoResolved

    System operating within expected parameters on the day of inspection.