Operations console
Prototype - no backend
All reports
Shade Analysis
RPT-2026-015 - performed 27 Jun 2026 by Faisal Shahzad
Health score
89
Measurements taken
6
0 outside reference
Findings
1
Customer visibility
Shared
Measurements
Each reading against the reference it is judged by.
| Measurement | Reading | Reference | Result |
|---|---|---|---|
| Open circuit voltage (string A) | 764 V | Within 5% of design | Pass |
| Short circuit current (string A) | 9.1 A | Within 8% of nameplate | Pass |
| Earth electrode resistance | 7.1 ohm | Below 5 ohm | Pass |
| Insulation resistance (DC+ to earth) | 47 Mohm | Above 1 Mohm | Pass |
| Max module temperature | 73 C | Below 25 C above ambient | Pass |
| Performance ratio on test day | 76% | Baseline 84% | Pass |
Context
- Customer
- Green Valley School
- Capacity
- 250.0 kW
- Work order
- JOB-2026-0011
- Technician
- Faisal Shahzad
Recommendation
System is healthy. Continue the current cleaning cycle and re-inspect in six months.
Score 89 / 100Findings
Defects recorded during this inspection.
No defects found
InfoResolvedSystem operating within expected parameters on the day of inspection.