Operations console

All reports

IV Curve Testing

RPT-2026-011 - performed 22 Mar 2026 by Danish Ali

Health score

58

Measurements taken

6

1 outside reference

Findings

1

Customer visibility

Shared

Measurements

Each reading against the reference it is judged by.

MeasurementReadingReferenceResult
Open circuit voltage (string A)756 VWithin 5% of designPass
Short circuit current (string A)10.4 AWithin 8% of nameplatePass
Earth electrode resistance8.1 ohmBelow 5 ohmPass
Insulation resistance (DC+ to earth)45 MohmAbove 1 MohmPass
Max module temperature51 CBelow 25 C above ambientPass
Performance ratio on test day65%Baseline 80%Outside reference
Context
Capacity
60.0 kW
Work order
JOB-2026-0019
Technician
Danish Ali
Recommendation

Schedule corrective repair within 14 days. Losses at the current rate exceed the cost of the fix.

Score 58 / 100
Findings

Defects recorded during this inspection.

  • Heavy soiling on lower rows

    MinorResolved

    Dust accumulation reducing output on the two lowest rows more than the rest of the array.