Operations console

All reports

Thermal Camera Inspection

RPT-2026-010 - performed 5 Mar 2026 by Naveed Iqbal

Health score

67

Measurements taken

6

1 outside reference

Findings

1

Customer visibility

Shared

Measurements

Each reading against the reference it is judged by.

MeasurementReadingReferenceResult
Open circuit voltage (string A)766 VWithin 5% of designPass
Short circuit current (string A)12.1 AWithin 8% of nameplatePass
Earth electrode resistance8.5 ohmBelow 5 ohmPass
Insulation resistance (DC+ to earth)14 MohmAbove 1 MohmPass
Max module temperature56 CBelow 25 C above ambientPass
Performance ratio on test day81%Baseline 82%Outside reference
Context
Capacity
25.0 kW
Work order
JOB-2026-0003
Technician
Naveed Iqbal
Recommendation

Schedule corrective repair within 14 days. Losses at the current rate exceed the cost of the fix.

Score 67 / 100
Findings

Defects recorded during this inspection.

  • No defects found

    InfoResolved

    System operating within expected parameters on the day of inspection.