Operations console

Customers

Falcon Logistics - Unit 1

32.0 kW Hybrid system in Lahore, commissioned 9 Oct 2024

System health

87

Performance ratio against baseline, less open defects

Generated (30 days)

3.4 MWh

93% of expected

Modelled soiling loss

9.0%

Last cleaned 2 Aug 2026

Performance ratio

76.9%

Baseline 83%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
32.0 kW
System type
Hybrid
Modules
58 x 555W Canadian Solar
Inverter
Solis S6-GR1P-32K (28.8 kW)
Battery
20 kWh
Tilt / azimuth
20 deg / 180 deg
Bird mesh
Installed
Tariff
Rs 40 per kWh
Net metering
Renewal due
NM reference
NM-2023-28988
Sanctioned
32 kW
AMC
Annual Plus
Open findings

Unresolved defects on this site.

  • String mismatch on MPPT 2

    Major

    String currents differ by 18 percent, pointing to partial shading or module degradation.

Work order history

8 visits

CodeServiceStatusAmount
JOB-2026-0020Waterless Panel CleaningIn progressRs 15.1K
JOB-2026-0123Inverter UpgradeRequestedRs 2.6L
JOB-2026-0164Performance TestingScheduledRs 9.0K
JOB-2026-0033Battery Check & ReplacementScheduledRs 19.0K
JOB-2026-0049Fuse ReplacementCompletedRs 1.9K
JOB-2026-0027Industrial Solar InstallationCompletedRs 24
JOB-2026-0050Performance TestingCompletedRs 9.0K
JOB-2026-0034Performance OptimizationCancelledRs 30.4K
Inspection reports

No reports for this site

Generation figures are modelled for the prototype from a fixed seed, so they are identical on every visit.