Operations console
Shahzad Motors - Unit 2
25.0 kW Off-Grid system in Multan, commissioned 8 Dec 2020
System health
29
Performance ratio against baseline, less open defects
Generated (30 days)
2.5 MWh
89% of expected
Modelled soiling loss
12.1%
Last cleaned 12 Apr 2026
Performance ratio
71.2%
Baseline 80%, target 82%
Ninety days. The dashed line is the design expectation; the gap between the lines is money.
Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.
Against the fleet target.
- Capacity
- 25.0 kW
- System type
- Off-Grid
- Modules
- 43 x 585W JA Solar
- Inverter
- Fronius Primo-25K (22.5 kW)
- Battery
- 5 kWh
- Tilt / azimuth
- 19 deg / 185 deg
- Bird mesh
- Not installed
- Tariff
- Rs 50 per kWh
- Net metering
- Not applied
- NM reference
- -
- Sanctioned
- -
- AMC
- No contract
Unresolved defects on this site.
Earthing resistance above limit
MajorMeasured 9.4 ohm against a 5 ohm reference. Earth pit needs re-treatment.
Burnt MC4 connector
CriticalDC connector on string C shows arcing damage. Replaced on site and adjacent connectors re-terminated.
Burnt MC4 connector
CriticalDC connector on string C shows arcing damage. Replaced on site and adjacent connectors re-terminated.
Burnt MC4 connector
CriticalDC connector on string C shows arcing damage. Replaced on site and adjacent connectors re-terminated.
Earthing resistance above limit
MajorMeasured 9.4 ohm against a 5 ohm reference. Earth pit needs re-treatment.
Burnt MC4 connector
CriticalDC connector on string C shows arcing damage. Replaced on site and adjacent connectors re-terminated.
7 visits
| Code | Service | Status | Amount |
|---|---|---|---|
| JOB-2026-0045 | Battery Check & Replacement | Requested | Rs 28.5K |
| JOB-2026-0023 | Solar Panel Repair | Completed | Rs 1.6L |
| JOB-2026-0125 | Lightning Protection | Completed | Rs 45.0K |
| JOB-2026-0150 | SPD (Surge Protection Device) Replacement | Completed | Rs 27.2K |
| JOB-2026-0021 | Combiner Box Repair | Completed | Rs 7.8K |
| JOB-2026-0081 | Waterless Panel Cleaning | Completed | Rs 11.2K |
| JOB-2026-0012 | Net Metering Assistance | Invoiced | Rs 35.0K |
No reports for this site
Generation figures are modelled for the prototype from a fixed seed, so they are identical on every visit.