Operations console

Customers

Shahzad Motors - Unit 1

50.0 kW On-Grid system in Multan, commissioned 19 Aug 2020

System health

81

Performance ratio against baseline, less open defects

Generated (30 days)

4.9 MWh

87% of expected

Modelled soiling loss

10.7%

Last cleaned 2 May 2026

Performance ratio

73.6%

Baseline 85%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
50.0 kW
System type
On-Grid
Modules
90 x 555W Canadian Solar
Inverter
Fronius Primo-50K (45.0 kW)
Battery
None
Tilt / azimuth
25 deg / 200 deg
Bird mesh
Not installed
Tariff
Rs 39 per kWh
Net metering
Not applied
NM reference
-
Sanctioned
-
AMC
No contract
Open findings

Unresolved defects on this site.

  • Inverter derating in afternoon peak

    Major

    Unit throttles above 46 degrees ambient. Cooling fins clogged with dust.

Work order history

5 visits

CodeServiceStatusAmount
JOB-2026-0156Combiner Box RepairIn progressRs 7.8K
JOB-2026-0071Moss & Dust RemovalScheduledRs 4.2K
JOB-2026-0017Panel ReplacementCompletedRs 18.9L
JOB-2026-0039IV Curve TestingCompletedRs 42.5K
JOB-2026-0147Hotspot DetectionCompletedRs 32.5K
Inspection reports

Generation figures are modelled for the prototype from a fixed seed, so they are identical on every visit.