Operations console

Customers

Kamran Yousaf

10.0 kW Hybrid system in Lahore, commissioned 25 Sep 2022

System health

78

Performance ratio against baseline, less open defects

Generated (30 days)

1.0 MWh

92% of expected

Modelled soiling loss

7.7%

Last cleaned 23 Jul 2026

Performance ratio

72.6%

Baseline 79%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
10.0 kW
System type
Hybrid
Modules
16 x 620W Jinko
Inverter
Growatt MIN-TL-X-10K (9.0 kW)
Battery
5 kWh
Tilt / azimuth
27 deg / 190 deg
Bird mesh
Not installed
Tariff
Rs 51 per kWh
Net metering
In process
NM reference
NM-2024-76338
Sanctioned
10 kW
AMC
Quarterly Care
Open findings

Unresolved defects on this site.

  • Inverter derating in afternoon peak

    Major

    Unit throttles above 46 degrees ambient. Cooling fins clogged with dust.

  • Loose structure bolt

    Minor

    Two mid-clamps below torque specification on the north row. Retorqued.

  • String mismatch on MPPT 2

    Major

    String currents differ by 18 percent, pointing to partial shading or module degradation.

Work order history

9 visits

CodeServiceStatusAmount
JOB-2026-0100Inverter UpgradeScheduledRs 82.0K
JOB-2026-0115IV Curve TestingRequestedRs 8.5K
JOB-2026-0057Insulation Resistance TestingScheduledRs 5.6K
JOB-2026-0001Insulation Resistance TestingDispatchedRs 5.6K
JOB-2026-0167Off-Grid Solar SystemCompletedRs 34
JOB-2026-0064Hybrid Solar SystemInvoicedRs 32
JOB-2026-0124Same-Day RepairCompletedRs 16.5K
JOB-2026-0053System Health AuditCompletedRs 12.0K
JOB-2026-0075Solar Panel RepairCompletedRs 60.8K
Inspection reports

Generation figures are modelled for the prototype from a fixed seed, so they are identical on every visit.