Operations console

All work orders

Complete Inspection & Checkup

JOB-2026-0165 - raised via AMC schedule 3 mo ago

InvoicedNormal priorityAnnual Plus AMC
Checklist

6 of 6 steps complete

Findings

Defects recorded on site. Unresolved criticals roll up to the operations overview.

  • Hotspot detected on string B

    Critical

    Thermal scan shows a cell running 27 degrees above array average. Bypass diode failure suspected.

    Open

  • Bird nesting under array

    Minor

    Pigeons nesting between modules and roof. Bird mesh recommended for the full perimeter.

    Open

Parts used

Consumed from van stock on this visit.

No parts consumed

Result

Generation either side of the visit.

+43 kWhper day

568 kWh before, 611 kWh after

Worth about Rs 49,020 a month at this site's tariff.

Assignment

Technician

Faisal Shahzad
Details
City
Rawalpindi
Capacity
150.0 kW
Raised
29 May 2026, 2:00 PM
Scheduled
31 May 2026, 5:00 AM
SLA due
30 May 2026, 2:00 PM (3 mo ago)
Completed
31 May 2026, 5:00 AM
Services
Complete Inspection & Checkup
Amount
Rs 7,500